How to clean the RO membrane of water treatment equipment?


Category:

Time of issue:2019-08-29

【 Summary Description 】Primarily use acidic agents for cleaning

How to clean the RO membrane of a water treatment device?

  Water treatment equipment How to clean the RO membrane?

  I. Primarily use acidic cleaning agents:

  1. Pour 200-300L of clean water into the membrane washing tank;

  2. Add 2-3kg of citric acid to the clean water and adjust it. Test with PH test paper. The water quality needs to be between 1-2. (If it is not within this range, you can continue to add a small amount of citric acid until the water quality is between 1-2);

  3. Perform cyclic cleaning according to the membrane washing procedure. Clean for 1-2H after starting, stop for 10-15min, then continue to turn on the membrane washing equipment and continue cleaning for 40-60min. Then discharge the cleaning solution, and rinse with pre-treated water. The water quality needs to be tested with PH test paper, and the water quality should be neutral (between 6-7). If the water quality does not reach the neutral range, continue rinsing until the water quality is qualified. The entire cleaning process takes about 3H. If the water volume increases and the pressure decreases, there is no need to clean with alkaline agents.

  II. Alkaline cleaning agent cleaning

  1. Pour 200-300L of clean water into the membrane washing tank;

  2. Add 2-3kg of sodium hydroxide to the clean water and adjust it. Test with PH test paper. The water quality needs to be between 9-10. (If it is not within this range, you can continue to add a small amount of sodium hydroxide until the water quality is between 9-10);

  3. Perform cyclic cleaning according to the membrane washing procedure. Clean for 1-2H after starting, stop for 10-15min, then continue to turn on the membrane washing equipment and continue cleaning for 40-60min. Then discharge the cleaning solution, and rinse with pre-treated water. The water quality needs to be tested with PH test paper, and the water quality should be neutral (between 6-7). If the water quality does not reach the neutral range, continue rinsing until the water quality is qualified. The entire cleaning process takes about 3H.

  Note:

  1. The water quality must be rinsed clean, and tested with PH test paper. The water quality needs to reach neutral 6-7. If it is not rinsed clean before proceeding to the next step, it will cause scaling inside the reverse osmosis water treatment equipment, affecting production.

  2. Note that the water temperature should not rise above 45℃ to avoid damaging the RO membrane. If the water temperature rises above 45℃, stop the machine and wait for it to cool before running again.

  The above is the RO membrane cleaning method in the reverse osmosis water treatment equipment. The reverse osmosis equipment needs to be cleaned regularly, and the quality of the reverse osmosis membrane directly affects the water quality effect of the equipment.

 


Shijiazhuang Tianwang Environmental Protection Technology Co., Ltd.

Shijiazhuang Tianwang Environmental Protection Technology Co., Ltd. is a high-tech enterprise specializing in the research and development, manufacturing and sales of water treatment equipment.

Contact Information

Production address: No. 9, Fengchan Road, Economic and Technological Development Zone, Shijiazhuang City

Office Address: 25th Floor, Block C, No. 310 Changjiang Avenue, Shijiazhuang High-tech Development Zone

Contact Number:
0311-89272359   0311-68039237

Enterprise Email:
twhbkj@163.com

Website: en.sjztwhb.com

Business License